Part I · Module 08 · PHYLUCE 1.7.3

UCE alignments

Separate the monolithic UCE FASTA by locus and align homologous sequences with MAFFT using phyluce_align_seqcap_align. The incomplete matrix is preserved so that occupancy can be evaluated later.

Objective

Produce one multiple-sequence alignment per UCE locus from the all-taxa-incomplete.fasta dataset generated in Module 07.

Alignment strategy

This tutorial uses MAFFT, which is the aligner recommended in the PHYLUCE documentation for general UCE analyses. We retain the incomplete matrix during alignment and evaluate matrix occupancy only after the loci have been aligned.

1. Activate PHYLUCE 1.7.3

conda activate phyluce-1.7.3

On Apple Silicon:

conda activate phyluce-1.7.3-x86

Confirm that the alignment tools are available:

phyluce_align_seqcap_align --help

mafft --version

2. Define the input and output

PROJECT="/path/to/my_UCE_project"

DATASET="$PROJECT/taxon-sets/all"
UCE_FASTA="$DATASET/all-taxa-incomplete.fasta"

ALIGNMENTS="$DATASET/mafft-nexus"
LOGS="$DATASET/log"

THREADS=8
N_TAXA=5
UCE_FASTA
Monolithic UCE FASTA produced in Module 07.
ALIGNMENTS
Directory that will contain one alignment for each retained UCE locus.
THREADS
Number of physical CPU cores available for alignment.
N_TAXA
Total number of samples included in the dataset.
Replace N_TAXA

N_TAXA=5 is only an example. Set this value to the actual number of samples listed in your [all] taxon set.

3. Align the UCE loci with MAFFT

phyluce_align_seqcap_align \
  --fasta "$UCE_FASTA" \
  --output "$ALIGNMENTS" \
  --taxa "$N_TAXA" \
  --aligner mafft \
  --cores "$THREADS" \
  --incomplete-matrix \
  --log-path "$LOGS"
--fasta
Monolithic FASTA containing all recovered UCE sequences.
--output
Directory where locus-by-locus alignments will be written.
--taxa
Total number of samples in the dataset.
--aligner mafft
Uses MAFFT for multiple-sequence alignment.
--cores
Number of physical CPU cores available to the alignment workflow.
--incomplete-matrix
Allows loci to contain fewer taxa than the complete dataset.
--log-path
Directory where PHYLUCE writes the alignment log.
PHYLUCE argument note

PHYLUCE documentation contains examples using both --fasta and --input in different pages. This tutorial uses --fasta, which is the argument documented in the PHYLUCE 1.7.3 daily-use workflow for aligning a monolithic UCE FASTA. Confirm the available arguments with phyluce_align_seqcap_align --help in your installed environment.

4. What happens during alignment?

PHYLUCE first separates the monolithic FASTA into groups of sequences belonging to the same UCE locus. Loci represented by fewer than three taxa are not aligned. The remaining loci are aligned independently with MAFFT.

By default, phyluce_align_seqcap_align also performs its standard edge-trimming procedure. This removes poorly aligned sequence at the ends of each locus while retaining the central aligned region.

Why keep the default trimming here?

The standard PHYLUCE workflow uses edge trimming during alignment. More aggressive or alternative trimming strategies can be evaluated later if required by a specific project, but they are not necessary for the general workflow presented here.

5. Expected output

The output directory contains one alignment per UCE locus. With the default output format, these files are written in NEXUS format.

taxon-sets/
└── all/
    ├── all-taxa-incomplete.fasta
    ├── mafft-nexus/
    │   ├── uce-1.nexus
    │   ├── uce-2.nexus
    │   ├── uce-3.nexus
    │   ├── ...
    │   └── uce-N.nexus
    └── log/

Count the number of retained alignments:

find "$ALIGNMENTS" \
  -maxdepth 1 \
  -name "*.nexus" \
  | wc -l

6. Summarize the alignments

PHYLUCE provides phyluce_align_get_align_summary_data to summarize thousands of alignments efficiently.

phyluce_align_get_align_summary_data \
  --alignments "$ALIGNMENTS" \
  --cores "$THREADS" \
  --log-path "$LOGS"

The summary reports the number of loci, total aligned length, sequence composition and information useful for evaluating matrix completeness.

7. Inspect a locus

Before moving forward, inspect at least one alignment manually:

FIRST_ALIGNMENT=$(find "$ALIGNMENTS" \
  -maxdepth 1 \
  -name "*.nexus" \
  | sort \
  | head -1)

echo "$FIRST_ALIGNMENT"

head -40 "$FIRST_ALIGNMENT"

Confirm that the alignment contains multiple taxa, nucleotide data and gaps where required, and that the sequence identifiers correspond to the expected samples.

8. Do not choose the final occupancy yet

The incomplete matrix created in Module 07 intentionally retains loci that are not present in every sample. Now that loci are aligned, we can determine how many loci would remain under different occupancy thresholds.

Next step

Module 09 will compare alternative completeness thresholds and build the final phylogenomic datasets. For example, a 75% matrix retains only loci containing at least 75% of the total taxa. The appropriate threshold depends on the dataset and analytical objective.

9. Common problems

Many loci are dropped before alignment

PHYLUCE requires at least three taxa for a locus to be aligned. A large number of dropped loci may therefore reflect low UCE recovery, a small taxon set or substantial missing data.

Too many CPU cores requested

Use only the number of physical cores actually available on the machine. The PHYLUCE documentation explicitly warns that requesting more cores than are available can generate errors.

Unexpected ambiguous bases

Review the alignment log and upstream sequence data. PHYLUCE applies checks to ambiguous sequence during the alignment workflow, and problematic loci may be removed.

10. Pre-flight check

✓ PHYLUCE 1.7.3 and MAFFT are available.
✓ N_TAXA matches the number of samples in the dataset.
✓ all-taxa-incomplete.fasta was used as input.
✓ --incomplete-matrix was retained during alignment.
✓ One NEXUS alignment was generated for each retained UCE locus.
✓ Alignment summary statistics were inspected.
✓ At least one locus was inspected manually.
✓ Final occupancy filtering has not yet been applied.

References and official documentation

PHYLUCE 1.7.3 — Tutorial I: UCE alignments

PHYLUCE 1.7.3 — UCE processing and incomplete matrices

PHYLUCE 1.7.3 — Alignment program list

MAFFT — official website

Software citation

Katoh K, Standley DM. 2013. MAFFT multiple sequence alignment software version 7: improvements in performance and usability. Molecular Biology and Evolution 30:772–780. doi:10.1093/molbev/mst010

Version policy

This module follows the PHYLUCE 1.7.3 alignment workflow: MAFFT, incomplete-matrix handling and locus-by-locus output. Occupancy filtering is deliberately postponed until the next module.

← Extracting UCE loci Next: Building phylogenomic datasets →